General information on lifting columns and actuators

What is a lifting column, and how does it work?

A Movetec lifting column is a telescopic aluminium column in which the lifting movement is driven by an electric motor and spindle inside the column. The column is supplied with 24 V DC from a Movetec MCB control box and operated via a desk panel, handset, foot switch or PLC. Built-in end stops automatically stop the column in its top and bottom positions.

What is the difference between the individual MAC columns?

Movetec offers a wide range of 2-stage and 3-stage columns, which can be freely configured in the Lifting Column Configurator at www.movetec.dk. As a general rule, the 2- stage column has a greater retracted (installation) height than the 3-stage column. Both column types can be configured with different forces and speeds, and both are available with or without mounting plates.

How much load can a lifting column lift?

The maximum load can be up to 10,000 N and is clearly stated on the type label of the column and in the Movetec datasheet for each model. Never exceed the specified maximum load, as this reduces service life and may trigger a safety stop. For eccentric loads, the permissible bending moment is decisive – see the datasheet.

What does stroke length mean?

The stroke is the distance the column can travel between fully retracted and fully extended position. The stroke is selected in the Lifting Column Configurator and stated in the datasheet. The total maximum height is the retracted height plus the stroke.

What is a Hall sensor, and what is it used for?

A Hall sensor is built into Movetec lifting columns with an 8-pin connector. It generates pulses which the MCB control box uses to determine the column position and to synchronise two or more columns. The Hall signal ensures that a table with several legs runs level and that PLC positioning is precise.

What voltage and current do the columns use?

Movetec lifting columns run on 24 V DC supplied by the MCB control box. The current consumption is stated on the type label. The duty cycle is typically 10–15 % (see datasheet) – e.g. max. 2 minutes of continuous operation followed by a pause to allow the system to cool down.

Installation and mounting

What should I be aware of when mounting the column?

Mount the column indoors on a stable, level surface at normal room temperature. Make sure the column is plumb and that there is at least 120 mm clearance to walls and surrounding objects to avoid the risk of crushing. Position the control box and handset so that they cannot be damaged during operation.

How close to a wall may the column be mounted?

Lifting columns must be placed at least 120 mm from walls or surrounding objects to avoid the risk of crushing. Check that there is no contact with the surroundings throughout the entire stroke.

How do I mount several columns for parallel operation?

For mechanically connected columns, the deviation in parallelism must be less than 0.5 mm per 1,000 mm. If this is not possible, one or more brackets must be sufficiently flexible to absorb the deviations. As standard, the columns are mounted with the inner tube facing upwards unless otherwise specified.

How may I attach equipment to the column?

Equipment may only be attached using the designated T-slots, bolt holes or mounting plates. Never use other fastening methods, and do not expose the column to heavy blows or impacts.

Can the columns be mounted free-standing?

Yes. For free-standing applications, Movetec offers base frames with adjustable feet as well as floor mounting plates as accessories, ensuring the column stands stable and level.

Which motor connector do the columns have, and how do I connect it?

All Movetec lifting columns have a MOLEX 8-PIN motor connector. The connector can only be inserted one way and must be pushed in until the latch clicks into place in the MCB control box. Never use force – if the connector is tight, check that it is oriented
correctly. Always make sure the connector is fully inserted and latched – poor contact is one of the most common reasons why a column does not respond.

Reset and synchronisation

How do I reset my lifting column?

As a rule, a reset is performed by holding down the DOWN button until all columns are fully retracted and the system has calibrated itself. Only release the button when the
movement has finished. The exact procedure depends on the MCB series – see the Movetec user manual for your control box.

The DOWN button works, but the system does not start – what do I do?

During a reset, it may be necessary to hold the DOWN button for a longer time – up to 30 seconds – before the system starts. Do not release the button too early. If the system still does not start, check the power supply and cable connections.

Why are the columns running unevenly / at different heights?

If one column is lower than the others, the system is typically out of synchronisation. Perform a full reset as described above. If the problem recurs, check cables, connectors and whether the columns are mounted under mechanical stress.

When should I perform a reset?

Perform a reset if the columns are out of synchronisation, if the system can only move downwards, if a column has been replaced or disconnected, or after an overload. A reset recalibrates the position and solves many common operating problems.

Why can the column only move downwards (possibly slowly) after a fault?

When the system can only move downwards – often at reduced speed – it has entered reset mode as a safety precaution. Perform a full reset. The system will then once again run synchronously at full speed in both directions.

Troubleshooting – the column does not move

My lifting column does not move at all – where do I start?

Follow this sequence: 1) Is the MCB control box powered? 2) Are all connectors correctly connected? 3) Is the motor connector (MOLEX 8-PIN) fully inserted and latched? 4) Are any cables damaged? 5) Does the control box or handset show an error code? If this does not solve the problem, test with another control box known to be working.

How do I check whether the system has power?

Check that the MCB control box is connected to a working power outlet and that the mains cable is properly seated in both the outlet and the control box. If necessary, test the outlet with another appliance. If there is power and the mains cable is fine but the handset does not respond, test with another MCB control box known to be working.

How do I know if the control box is defective?

Test the system with another MCB control box of the same series known to be working. If the columns work with the new control box, the fault lies in the control box; if they still do not work, the fault lies in the column, cable or handset.

The column stops and can only move in the opposite direction – why?

Typically, the column has reached its top or bottom position, or there is a physical obstruction. On MCB-JSM and MCB-LC, an activated collision sensor may also have stopped the movement (see section 10). If the column always stops at the same point
without any physical obstruction, a virtual (software) end stop may have been set in the control box – contact Movetec.

The column does not reach its full stroke – what is the cause?

Check whether the column is hitting other objects. If it consistently stops at the same point without obstruction, a limit has most likely been set in the control box (virtual end
stop or position limit via Modbus). Check the settings or contact Movetec.

Overload and obstruction

The column can only move downwards after heavy loading – why?

In the event of an overload, the system enters protection mode. Reduce the load to the maximum load stated on the type label, and then perform a reset. Also check that the column is not in contact with other objects.

What happens if I exceed the maximum load?

The MCB control box stops the movement to protect the motor and electronics. Remove the excess load, check that the load is within the type label rating, and perform a reset.

The column stopped because it hit an object – what do I do?

Remove the obstruction, and then run the column in the opposite direction of the obstruction. Make sure there is free space throughout the range of movement before continuing. If additional protection of the equipment is required, a collision sensor can be activated on MCB-JSM and MCB-LC (see section 10).

How do I avoid overloading the system?

Keep the load within the type label rating, pay attention to eccentric loads, observe the duty cycle, and distribute the load evenly across the columns in a parallel system.

Movetec control boxes (MCB) and handsets

Which control boxes does Movetec offer?

Movetec offers four control box series: the MCB-JSM series (Movetec’s own series for desk and workstation solutions), the MCB-TC series, the MCB-Compact series and the MCB-LC series, which is Movetec’s series for industrial positioning with Modbus
communication and PLC integration.

Which MCB series should I choose?

For height-adjustable desks and workstations with manual operation, MCB-JSM, MCB-TC or MCB-Compact is recommended, depending on the number of columns and functions. If the columns need to be positioned precisely from a PLC, choose MCB-LC with
Modbus and the Movetec TCP/IP adapter. If the PLC only needs to know the position, a wire sensor can be a simple solution. If a collision or tilt sensor is required, choose MCBJSM or MCB-LC. Contact Movetec for advice.

Which handsets can be used?

Movetec supplies desk panels, handsets and foot switches – e.g. the MCP handsets in the JSM series with up/down and memory functions. The handset must match the selected MCB series. Brackets are also available for mounting the control box in the Tslots of the column.

What does the error code on my MCB control box mean?

Error codes are shown in the handset display or can be read out via Modbus (MCB-LC). The meaning of the error codes is described in the Movetec user manual for the relevant MCB series. Note the code and contact Movetec if you cannot find the explanation.

What does a Hall/position error mean?

A Hall or position error means that the control box is not receiving correct position pulses from one or more columns – e.g. due to a loose connector, a damaged cable or a blocked motor. Check cables and connectors, switch the system off and on, and perform a reset. If the error persists, contact Movetec.

Parallel operation of several columns

How many columns can run in parallel?

The number depends on the selected MCB control box and the number of motor channels. All columns in a parallel system must be of the same type and correctly connected. Contact Movetec for the right control box for the desired number of legs.

The system detects the wrong number of columns – what do I do?

The control box checks the number of connected columns at start-up. The error typically occurs if a column has been disconnected, or if a column has been connected/disconnected with the power on. Switch off the power, check all connectors,
switch on again and perform a reset.

Why must parallel columns be mounted so precisely?

For synchronisation to work, the mechanical parallelism must be within 0.5 mm per 1,000 mm. If the columns are mounted under stress, they cannot keep pace with each other, and the system will repeatedly fall out of synchronisation.

Positioning with MCB-LC, Modbus and TCP/IP

What is the MCB-LC series?

MCB-LC is Movetec’s control box series for industrial positioning. The control box is programmed with Modbus, so the position, speed and status of the columns can be controlled and monitored from a PLC, an HMI or a higher-level machine control system – instead of simple up/down operation only.

What can I use positioning for?

Typical applications include automatic adjustment of working height per operator or product, machines and fixtures that need to move to fixed positions, test equipment and laboratory setups, and integration in production lines where the height is controlled by the PLC.

What is the Movetec TCP/IP adapter?

The TCP/IP adapter is Movetec’s gateway between the MCB-LC control box and your network. It retrieves Modbus data from the control box and makes it available to the PLC over Ethernet (Modbus TCP). This allows the PLC to send commands and read
position, status and errors without additional serial cabling.

Which PLCs can communicate with MCB-LC?

All PLCs and HMI systems that support Modbus TCP as client/master can communicate with MCB-LC via the TCP/IP adapter. If your PLC only supports analogue inputs, a wire sensor (section 9) may be the alternative. Contact Movetec if in doubt.

How do I connect MCB-LC to my PLC?

1) Connect the columns and power to the MCB-LC. 2) Connect the TCP/IP adapter to the communication port of the control box. 3) Connect the adapter to the PLC network with an Ethernet cable. 4) Set the IP address of the adapter in the same subnet as
the PLC. 5) Set up the Modbus TCP connection in the PLC. All settings are described in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk.

How do I set the IP address of the TCP/IP adapter?

The adapter is supplied with a default IP address, which is stated in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk. Change it to a free address in your own network, and make sure the subnet mask matches that of the PLC. Two devices must never have the same IP address on the network.

Where can I find the Modbus registers and the technical description?

All registers for commands, target position, actual position, speed, status and error codes are described in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk. Always download the latest version before setting up the PLC program.

How do I send the column to a specific position?

The PLC writes the desired target position to the control box and then activates the movement with a command. The control box runs the columns synchronously to the position and stops automatically. The actual position and the ‘in position’ status can be read continuously. The procedure is described in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk.

How do I read the current position of the column?

The actual position is read from the MCB-LC via Modbus TCP. The position is based on the Hall pulses, and the unit and register are described in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk. Read the position
cyclically in the PLC program for continuous monitoring.

Can I store fixed positions?

Yes. Fixed positions can be handled in the PLC program as target positions that are sent to the MCB-LC as required. See the options in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk, or contact Movetec for advice on your application.

How do I read errors and status via Modbus?

The MCB-LC provides status and error information that the PLC can read cyclically – e.g. ‘running’, ‘in position’, ‘overload’ and ‘position error’. Error codes and their handling are described in the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk.

The PLC cannot connect to the control box – what do I do?

Check: 1) that the adapter is powered and the link LED on the network port is lit, 2) that IP address and subnet match the PLC, 3) that there is no IP conflict, 4) that the Modbus settings in the PLC correspond to the document “Movetec ModBus Interface”, available under Downloads at www.movetec.dk, and 5) that the connection between the adapter and the MCB-LC is properly seated. If necessary, test with a Modbus test tool on a
PC.

The position is inaccurate or drifting – what do I do?

Perform a reset/reference run to the bottom position so the control box resets the position. Also check cables and connectors, and make sure the columns are not overloaded
or under mechanical stress. Repeat the positioning and compare with a manual measurement.

Can I control several MCB-LC control boxes from the same PLC?

Yes. Each TCP/IP adapter is assigned its own IP address, and the PLC establishes a Modbus TCP connection to each one. In this way, several tables or stations can be controlled and monitored from one system.

Can the Modbus communication be used as an emergency stop?

No. Modbus is not a safety function. Emergency stop and other safety functions must be implemented with a separate, hard-wired safety circuit in accordance with the Machinery Directive and your risk assessment. It is also recommended to monitor the
communication in the PLC and stop the movement in the event of a timeout.

Analogue positioning with wire sensor (4–20 mA / 0–10 VDC)

What is a wire sensor?

A wire sensor is a position transducer that measures the height of the column via a draw wire and converts it into an analogue signal. All Movetec lifting columns can be configured with a wire sensor, so that the current position of the column can always be read.

Which output signals can the wire sensor provide?

The wire sensor is supplied with either a 4–20 mA current signal or a 0–10 VDC voltage signal. The signal is linear in relation to the column position, so the lowest value corresponds to the column fully retracted and the highest to the column fully extended.

Should I choose 4–20 mA or 0–10 VDC?

4–20 mA is recommended for long cables and in environments with electrical noise, as the current signal is robust against voltage drops and interference – and a signal below 4 mA clearly indicates a cable break. 0–10 VDC is suitable for short cable runs, or if the analogue input of the PLC only supports voltage. Choose the signal that matches your PLC input.

How do I use the wire sensor with a PLC?

The wire sensor is connected to an analogue input on the PLC, which then continuously knows the position of the column. It is a simple solution when the PLC requires a position value – e.g. to stop at specific heights, document working height or monitor
position – without having to set up bus communication.

How do I scale the signal in the PLC?

Run the column fully down and note the analogue value, then run it fully up and note the value again. Scale linearly between the two points so that the PLC shows the position in mm. Because the signal is linear, two calibration points are sufficient.

When should I choose a wire sensor rather than Modbus via MCB-LC?

A wire sensor is the right choice when the PLC simply needs to know the column position via a standard analogue input. MCB-LC with Modbus and the TCP/IP adapter is chosen when the PLC also needs to send the column to specific positions and read status
and errors. The two solutions can be combined if an independent position measurement is required.

The signal from the wire sensor is unstable or incorrect – what do I do?

Check: 1) that the sensor is correctly powered, 2) that the signal cable is shielded and routed separately from motor and mains cables, 3) that the PLC input is set to the same signal type (mA or V) as the sensor, and 4) for 4–20 mA: a signal below 4 mA indicates a cable break or missing supply. Contact Movetec if the fault persists.

How do I order columns with a wire sensor?

Specify the wire sensor and signal type (4–20 mA or 0–10 VDC) when ordering, so the column is delivered configured. If you wish to add a wire sensor to an existing installation, contact Movetec for advice.

Collision and tilt sensor (material protection)

What is the collision and tilt sensor?

The collision and tilt sensor is a function that can be activated in the Movetec MCB-JSM series and MCB-LC series. It monitors the system during movement and stops the movement if the table or structure hits an object, or if it reaches an abnormal inclination.

What does the collision sensor do?

The collision sensor detects when the table or lifted structure hits an object during movement, e.g. a shelf, a window sill or equipment under the tabletop. The control box then stops the movement, limiting damage to equipment, tabletop and surroundings.

What does the tilt sensor do?

The tilt sensor detects if the table or structure tilts more than normal during movement – e.g. if one side is blocked while the other side continues. The control box stops the movement before the structure is twisted or overloaded, and before objects on the table slide or fall over.

Does the collision and tilt sensor protect people?

No. The collision and tilt sensor is exclusively a material protection designed to limit damage to equipment, tabletops and surroundings. It is not personal protection and must never be used as a safety function against crushing or other personal injury. Personal safety must be ensured through correct design, clearance (at least 120 mm), risk assessment and any separate safety functions.

Which Movetec control boxes support the collision and tilt sensor?

The function can be activated in the MCB-JSM series and the MCB-LC series. If you want collision or tilt protection in your solution, one of these two control box series must be selected.

How do I get the collision and tilt sensor activated?

Specify the collision and/or tilt sensor when ordering MCB-JSM or MCB-LC, so that the control box is delivered with the function activated. If you want the function activated or adjusted on an existing control box, contact Movetec.

The table has been stopped by the collision or tilt sensor – what do I do?

Remove the cause of the stop – e.g. an object in the range of movement or an obstruction under the table. Then run the table in the opposite direction and continue normal operation. If the columns have fallen out of synchronisation, perform a reset (see section 3).

The table stops even though there is no collision – why?

Unwanted stops can be caused by unevenly distributed or eccentric loads, columns mounted under mechanical stress, an uneven floor or impacts against the table during movement. Check the load, mounting and floor. If the unwanted stops continue,
contact Movetec for a review of the control box settings.

Maintenance, cleaning and service life

Does the lifting column require maintenance?

The column normally only requires ordinary cleaning. There are no internal parts that the user needs to lubricate or service.

How do I clean the column correctly?

Use a soft cloth with a mild detergent. Avoid solvents and high-pressure cleaning, and wipe dry so that no moisture remains on the sliding surfaces of the telescope.

How often should I inspect the system?

Inspect regularly – preferably daily in industrial environments – for damage to cables, connectors and the control box. Loose or damaged cables are one of the most common causes of downtime.

What extends the service life of my lifting column?

Keep the load within the maximum, observe the duty cycle, avoid eccentric loads beyond the permissible limit, and keep the system clean and dry. Regular reference runs ensure precise positioning.

Safety

What are the most important safety rules?

Make sure there is no risk of crushing between the lifting mechanism and the surroundings. Never place objects or body parts in the range of movement of the column. The force of the columns can cause serious personal injury and material damage. Note that the collision and tilt sensor is not personal protection.

May I dismantle the lifting column myself?

No. Internal components may spring out and cause personal injury. All dismantling and servicing must be carried out by Movetec or authorised personnel – otherwise the warranty will be void.

May lifting columns be used to lift people?

No. Movetec lifting columns are intended for adjusting the height of workstations, tables, fixtures and machines. They must not be used for lifting people and must not be used outside the specified areas of application.

What should I be aware of when welding near the column?

Disconnect and shield the control box and cables, and keep them away from welding equipment and welding cables. Otherwise, there is a risk of permanent damage to the electronics.

Ordering, spare parts and support

How do I find the correct item number?

The item number and type designation are shown on the type label of the column and the control box as well as in the Movetec datasheet. All columns, MCB control boxes, handsets and accessories have a Movetec item number – always state it when ordering. New columns can be configured in the Lifting Column Configurator at www.movetec.dk.

Can I order a control box, handset or adapter separately?

Yes. MCB control boxes, handsets, TCP/IP adapters, cables, brackets, mounting plates and other accessories can be ordered separately from Movetec. State the type label information and configuration (number of columns, MCB series, wire sensor or collision/tilt sensor if applicable), so we can deliver the correct part.

What do I do in case of transport damage?

Inspect the goods immediately upon receipt and report any transport damage directly to the carrier. Store unopened goods in a dry and dust-free place.

Where can I get technical support?

Contact Movetec Solutions ApS technical support with the type label information, MCB series, symptom and any error codes – for positioning tasks, please also state the PLC type, IP configuration or the signal type of the wire sensor. Contact: info@movetec.dk · www.movetec.dk · phone +45 64 89 28 05.